Profiles:             Tower, Rack-Mount, or Modular
Rating:               2kVA - 600kVA
Voltage:             230Vac or 400Vac
Frequency:        50Hz
Power Factor:    0.99 input, 0.9 - 1.0 output

 


Rate and Review this product

Input                                                                                                     
Voltage      CV-2 Model:                         220/230/240 Vac (1-phase)
  CV-4 & CV-6 Models :         380/400/415 Vac (3-phase)
Tolerance  Normal Over-voltage:       +10%
  Withstand Over-voltage:   +15% (20% max limit)
  Normal Under-voltage:      - 24% (without de-rating)
  Withstand Low-voltage:      - 43% (with de-rating)
Power Factor 0.99
Frequency                     40 - 70Hz 
   
Output    
Voltage      CV-2 & CV-4 Models:  220/230/240Vac±1.5%, selectable (1-ph)
  CV-6 Model:             380/400/415 Vac ± 1.5%, selectable (3-ph)
Power Factor 0.9 (standard)
  1.0 (option)
Frequency                     50/60Hz ± 0.01% (On Battery)
Transfer Time     0 ms
Efficiency 95 - 96%, 3ph (AC-AC & DC-AC)
  90 - 93.5%, 1ph (AC-AC & DC-AC)
Waveform                      Pure Sine Wave
THDi (Full Load) Linear Load ≤ 1%;     Non-linear Load ≤ 5.5%  
Crest Factor  3 : 1
Bypass Facility Maintenance Bypass and Static Bypass
   
DC Bus / DC Functions:                     
3-Phase ±240Vdc (Settable from ±192 to ±264V)
1-Phase 36V / 72V / 96V / 192Vdc
Cold-Start Function Yes, available option
DC Charging Power 20% of UPS rated power (LCD programmable limit up to 20%)
Battery Charging in OFF Mode    Yes
Battery Type Sealed, Maintenance-free VRLA 
   
LCD Interface:             
Metering / Indications for Mains: Voltage, Current, Frequency (input / output)
  Load %
  Battery: Voltage, Charge / Discharge Current
  General Status: Alarm, Events History, etc
Settings Interface Programmable settings (by trained / qualified personnel)
   
Communication:             
Interfaces  RS232, USB*, SNMP*, Relay Contacts*                (* Option)
   
Overload (for 3-phase Models)  
100~110%   60mins
110~125% 10mins
125~150%   1min
>150% 200ms
   
Environment:        
Temperature       0 ~ 40o
Humidity       20 ~ 90% Non-condensing
Audible Noise (1m)        <48dB (<70% load) : 10 ~ 15kVA
  <55dB : 10 ~ 40kVA 
  68dB (100% load) : 60 – 150kVA
  72dB (100% load) : 200 – 600kVA
  55dB (100% load) : RM20-60kVA
IP Class IP 20
   
Physical:  
Dimensions  (mm)         10-15kVA             :       250 x 840 x 715
(W x D x H) mm 20-30kVA             :       350 x 740 x 1340
  40kVA                  :       500 x 840 x 1440 
10-40kVA 60kVA                  :       600 x 980 x 950 
Complete with internal battery 80-100kVA           :       600 x 980 x 1150
  120kVA                :       600 x 980 x 1140
  150-200kVA         :       650 x 960 x 1600 
60-600kVA 250-300kVA         :       650 x 960 x 2000
Excludes external battery 400-500kVA         :       1300 x 1100 x 2000
UPS module only RM150kVA           :       600 x 1100 x 1600
  RM250kVA           :       600 x 1100 x 2000
  RM500kVA           :       650 x 960 x 2000
  400-500kVA         :       2000 x 1100 x 2000
  RM180-300kVA    :       600 x 1100 x 2000
  RM600kVA           :       2000 x 1050 x 2000
   
Weight (Kg) 10-15kVA             :       150
  20-30kVA             :       290
  40kVA                  :       400
10-40kVA 60kVA                  :       170
Complete with internal battery 80-100kVA           :       210
  120kVA                :       266
  150kVA                :       305
60-600kVA 200kVA                :       350
Excludes external battery 250kVA                :       445
UPS module only 300kVA                :       490
  400kVA                :       810
  500kVA                :       900
  RM150kVA           :       360
  RM250kVA           :       540
  RM500kVA           :       1300
  RM180-300kVA    :       370
  RM300kVA           :       560
  RM600kVA           :       1340
Profiles:       Rack or Tower Configuration
Range:        10 – 600kVA (3-phase); 2 – 20kVA (1-phase)
Fully Programmable (as UPS, power conditioner, frequency converter, paramerters limits, etc)
Active Power Factor Correction (0.99 input P.F)
Operation:    Double-conversion Online
Very High Efficiency: Up to 96%  
Off-mode Charging  
Cold Start Capability  
High Power Density  
18 Months warranty (excluding battery)
Excellent support  
Very wide input voltage tolerance  
Sleek Form Factor with Rugged Design
Large LCD Interface for multiple functional status details

Powerex Limited warrants Vectronic® products to be free from defects in materials and workmanship under the conditions of normal use. The warranty period for each product range is as stated below. Powerex Limited guarantees the proper operation of Vectronic® products when used in accordance with the operating manual and within the limits of performance specifications.


Duration of Warranty

This warranty applies to the following Vectronic® product models respectively, for all distributors and end users, valid from the purchase date duly evidenced by invoice or receipt, for all products sourced through authorized or proper channels:

  • Vectronic Line-interactive UPS    – 24 months
    • EG 650-3000VA
    • DG 600-3000VA
       
  • Vectronic Online UPS, 1ph                        – 18 months
    • FS 1-20kVA
    • FS-R 1-20kVA
    • FS-V 1-20kVA
    • C-V 2-10kVA
  • Vectronic Online UPS, 3ph            – 18 months
    • C-V 10-600kVA
  • Vectronic AVR                                 – 24 months
    • 1-phase 5-30kVA
    • 3-phase 10-5000kVA


Limitations of Warranty

  1. This Warranty is limited to repairs or replacement of product in the event of fault, defect or malfunction under normal conditions of use, at no charge, for warranty parts, components, spares, labour, services, or replacement units in part or whole, at designated Vectronic® Warranty Centre(s) or Authorized Affiliate Service Locations, provided that repairs or replacement decision is at the discretion of Powerex Limited. Any parts used or replaced under this warranty may be new, factory re-conditioned or workshop certified.

 

Below are designated Warranty Centres

    • Melange Technology Limited (Vectronic® Warranty Centre)

 63, Kudirat Abiola Way, Oregun

Ikeja, Lagos Nigeria

E-mail: support@melange-technology.com

 

    • Powerex Limited  

 932A Folashade Abike Street, Omole Phase II

Lagos Nigeria

E-mail: support@powerex-limited.com

 

  1. Irrespective of warranty product repairs or replacement in part or whole at the discretion of Powerex Limited, the original warranty period shall apply; warranty service shall not extend the original warranty period in any way.

 

  1. Powerex Limited shall make good warranty product defect or fault without any liability for consequential or third-party loss or damage from product fault or downtime to supported load, operations, processes or systems. For the avoidance of doubt, liability is limited only to Vectronic product; to repair, restore or replace.

 

 

Limitations and Exclusions

  1. This Limited Warranty does not cover faults arising from negligence, abuse, misuse, improper storage, poor installation, user modifications or unapproved testing. Also, warranty does not cover unauthorized repairs or attempts to repair or improvise; operation with wrong input supply parameters; or unacceptable, deplorable, or corrosive site ambient conditions. Furthermore, installation, operation or commissioning by unqualified or unauthorized service personnel may imperil warranty, just as sabotage, accidental or wilful damage, fire, inferior or compromised external accessories, failure to adhere to approved local electrical codes, or any use outside the intended, specified or recommended applications.
     
  2. Warranty applies to the purchaser and neither extends nor is transferable to other parties directly or indirectly.
     
  3. For UPS products, extended storage periods after purchase without occasional charge may compromise the battery. It is the responsibility of user or purchaser to connect their UPS to mains periodically, preferably quarterly, if in storage for several months without use, to avoid voiding warranty.
     
  4. This Limited Warranty excludes fault or damage from fair wear and tear on product parts or components that normally degrade with regular or heavy use, like UPS battery, AVR brush / contact assembly, and such parts.
     
  5. Traceability is crucial to establishing genuineness of warranty claims. A claim under warranty must therefore be for a product with clear, unaltered product label indicating the Serial Number, Model and Capacity, accompanied with proof of purchase indicating date and seller or distributor to avoid delays.
     
  6. Warranty applies ONLY to Vectronic products fully paid for by claimant(s).
     
  7. The right to modify or vary the terms of this Limited Warranty is vested only in Powerex Limited. No variation to these terms is valid except in writing, and duly executed by authorized representative(s).  
     

Optional Warranty Terms

  1. On-site Warranty Service is available subject to pre-agreed terms
  2. Extended Warranty period available up to 5 years, or more
  3. Other warranty and support flexibilities available on request

 


Rating and Reviews

1.0 / 5

5
0%
0
4
0%
0
3
0%
0
2
0%
0
1
60%
3

Oct 29, 2024
My Vectronic ups is not charging the battery. It's not backing up

Sep 17, 2022
Are the batteries internal or external, what is the battery size?

Sep 05, 2022
On a screen fl flowing out voltage to the load

Related Products

FS-T

View Item

DG 600-3000VA

View Item

EG 650-3000VA

View Item

FS-R/V 1-10kVA

View Item